		<id>http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=286</id>
		<title>Wide Range Voltage Equipment</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=286"/>
		<updated>2020-09-06T22:36:58Z</updated>

		<summary type="html">&lt;p&gt;Teun: Added Moxa switch&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;This is the start of a list for potential equipment that can handle a wide range of voltages.&lt;br /&gt;
I suggest that equipment is selected to have a wide voltage range so that power surges or brownouts don't cause equipment failure.&lt;br /&gt;
&lt;br /&gt;
Please add to the list, mentioning whether you have actually used the equipment, and whether it was any good.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Make !! Model !! Type !! Min. Voltage !! Max. Voltage !! Min. Power !! Max. Power !! Comments !! Actually used by&lt;br /&gt;
|-&lt;br /&gt;
| StarTech || [https://www.startech.com/uk/Cards-Adapters/USB-3.0/Hubs/~ST7300USBME ST7300USBME] || USB Hub / Charger || 7V || 48V || ? || 350W ? || Worked nicely at CCCamp 2019|| [[User:Chewie]]&lt;br /&gt;
|-&lt;br /&gt;
| SystemBase || [https://www.sysbas.com/en/portfolio-item/sg-2021dilall/ SG-2021DIL] || Serial-&amp;gt;LAN Converter || 12V || 48V || 2W || 2W || Other Models are available with more or fewer ports|| &lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://images-na.ssl-images-amazon.com/images/I/A1cHD8nc9FL.pdf TI-G102 (v1.0R)] || Gigabit Switch || 12V || 56V || 5.76W || 5.76W || 10x 1GB, 2 x SFP, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://www.trendnet.com/products/industrial-fiber-switches/TI-PG62B TI-PG62B] || Gigabit Switch || 12V || 56V || 5.76W || 120W || 4x 1GB PoE+, 2 x SPF, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| Moxa || [https://www.moxa.com/getmedia/5a5f5549-492c-4f37-ab04-9380399b8b59/moxa-eds-2008-el-series-datasheet-v1.2.pdf EDS-2008-EL] || Ethernet Switch || 9.6V || 60V || 3W || 3W || 8x Fast Ethernet or 1x Multi-Mode + 7FE, dual power input + alarm&lt;br /&gt;
|-&lt;br /&gt;
| Mikrotik || [https://mikrotik.com/product/rb450gx4 RB-450Gx4] || PoE Gigabit Router || 10V || 57V || 4W || 16W || 5x 1Gb (1x 802.3at in, 1x PoE passthrough), 1x RS232, 2x DC input. 4x716MHz, 1G RAM, 512M Flash || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Meanwell || [https://www.meanwell.com/Upload/PDF/SD-350/SD-350-SPEC.PDF SD-350C] || DC-DC Converter || 36V || 72V || 5W? || 350W || 1x 4.5~5.5V/60A, 11~16V/27.5A, 23~30V/14.6A or 43~53V/7.3A output || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Meanwell || [https://www.meanwell.com/Upload/PDF/LDD-H/LDD-H-SPEC.PDF LDD-H series] || DC-DC LED Driver || 9V || 56V || 2W || 56W || Models with 300~1000mA CC, Vout: 2V~(Vin-3V). PWM (open collector/5V) in: 0.1~1KHz ||&lt;br /&gt;
|-&lt;br /&gt;
| Victron || [https://www.victronenergy.com/upload/documents/Datasheet-Orion-Tr-DC-DC-converters-isolated-100-250-400W-EN.pdf Orion-TR 48] || DC-DC Converter || 32V || 70V || 5W || 320W || Models with 10~15V, 20~30V, 40~60V Isolated || &lt;br /&gt;
|-&lt;br /&gt;
| Victron || [https://www.victronenergy.com/upload/documents/MultiPlus-II-to-MultiGrid-and-MultiPlus-comparison-EN.pdf Multiplus/-grid] || DC-AC Inverter/Charger || 38V || 66V || 25W || 5000W || Inverter/Charger with grid synchronisation || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Example || Example || Example || Example || Example || Example || Example || Example&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=285</id>
		<title>Wide Range Voltage Equipment</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=285"/>
		<updated>2020-09-06T21:50:38Z</updated>

		<summary type="html">&lt;p&gt;Teun: Added Victron products&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;This is the start of a list for potential equipment that can handle a wide range of voltages.&lt;br /&gt;
I suggest that equipment is selected to have a wide voltage range so that power surges or brownouts don't cause equipment failure.&lt;br /&gt;
&lt;br /&gt;
Please add to the list, mentioning whether you have actually used the equipment, and whether it was any good.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Make !! Model !! Type !! Min. Voltage !! Max. Voltage !! Min. Power !! Max. Power !! Comments !! Actually used by&lt;br /&gt;
|-&lt;br /&gt;
| StarTech || [https://www.startech.com/uk/Cards-Adapters/USB-3.0/Hubs/~ST7300USBME ST7300USBME] || USB Hub / Charger || 7V || 48V || ? || 350W ? || Worked nicely at CCCamp 2019|| [[User:Chewie]]&lt;br /&gt;
|-&lt;br /&gt;
| SystemBase || [https://www.sysbas.com/en/portfolio-item/sg-2021dilall/ SG-2021DIL] || Serial-&amp;gt;LAN Converter || 12V || 48V || 2W || 2W || Other Models are available with more or fewer ports|| &lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://images-na.ssl-images-amazon.com/images/I/A1cHD8nc9FL.pdf TI-G102 (v1.0R)] || Gigabit Switch || 12V || 56V || 5.76W || 5.76W || 10x 1GB, 2 x SFP, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://www.trendnet.com/products/industrial-fiber-switches/TI-PG62B TI-PG62B] || Gigabit Switch || 12V || 56V || 5.76W || 120W || 4x 1GB PoE+, 2 x SPF, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| Mikrotik || [https://mikrotik.com/product/rb450gx4 RB-450Gx4] || PoE Gigabit Router || 10V || 57V || 4W || 16W || 5x 1Gb (1x 802.3at in, 1x PoE passthrough), 1x RS232, 2x DC input. 4x716MHz, 1G RAM, 512M Flash || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Meanwell || [https://www.meanwell.com/Upload/PDF/SD-350/SD-350-SPEC.PDF SD-350C] || DC-DC Converter || 36V || 72V || 5W? || 350W || 1x 4.5~5.5V/60A, 11~16V/27.5A, 23~30V/14.6A or 43~53V/7.3A output || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Meanwell || [https://www.meanwell.com/Upload/PDF/LDD-H/LDD-H-SPEC.PDF LDD-H series] || DC-DC LED Driver || 9V || 56V || 2W || 56W || Models with 300~1000mA CC, Vout: 2V~(Vin-3V). PWM (open collector/5V) in: 0.1~1KHz ||&lt;br /&gt;
|-&lt;br /&gt;
| Victron || [https://www.victronenergy.com/upload/documents/Datasheet-Orion-Tr-DC-DC-converters-isolated-100-250-400W-EN.pdf Orion-TR 48] || DC-DC Converter || 32V || 70V || 5W || 320W || Models with 10~15V, 20~30V, 40~60V Isolated || &lt;br /&gt;
|-&lt;br /&gt;
| Victron || [https://www.victronenergy.com/upload/documents/MultiPlus-II-to-MultiGrid-and-MultiPlus-comparison-EN.pdf Multiplus/-grid] || DC-AC Inverter/Charger || 38V || 66V || 25W || 5000W || Inverter/Charger with grid synchronisation || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Example || Example || Example || Example || Example || Example || Example || Example&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=284</id>
		<title>Wide Range Voltage Equipment</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=284"/>
		<updated>2020-09-06T20:31:45Z</updated>

		<summary type="html">&lt;p&gt;Teun: Added Meanwell LDD series LED driver&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;This is the start of a list for potential equipment that can handle a wide range of voltages.&lt;br /&gt;
I suggest that equipment is selected to have a wide voltage range so that power surges or brownouts don't cause equipment failure.&lt;br /&gt;
&lt;br /&gt;
Please add to the list, mentioning whether you have actually used the equipment, and whether it was any good.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Make !! Model !! Type !! Min. Voltage !! Max. Voltage !! Min. Power !! Max. Power !! Comments !! Actually used by&lt;br /&gt;
|-&lt;br /&gt;
| StarTech || [https://www.startech.com/uk/Cards-Adapters/USB-3.0/Hubs/~ST7300USBME ST7300USBME] || USB Hub / Charger || 7V || 48V || ? || 350W ? || Worked nicely at CCCamp 2019|| [[User:Chewie]]&lt;br /&gt;
|-&lt;br /&gt;
| SystemBase || [https://www.sysbas.com/en/portfolio-item/sg-2021dilall/ SG-2021DIL] || Serial-&amp;gt;LAN Converter || 12V || 48V || 2W || 2W || Other Models are available with more or fewer ports|| &lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://images-na.ssl-images-amazon.com/images/I/A1cHD8nc9FL.pdf TI-G102 (v1.0R)] || Gigabit Switch || 12V || 56V || 5.76W || 5.76W || 10x 1GB, 2 x SFP, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://www.trendnet.com/products/industrial-fiber-switches/TI-PG62B TI-PG62B] || Gigabit Switch || 12V || 56V || 5.76W || 120W || 4x 1GB PoE+, 2 x SPF, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| Mikrotik || [https://mikrotik.com/product/rb450gx4 RB-450Gx4] || PoE Gigabit Router || 10V || 57V || 4W || 16W || 5x 1Gb (1x 802.3at in, 1x PoE passthrough), 1x RS232, 2x DC input. 4x716MHz, 1G RAM, 512M Flash || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Meanwell || [https://www.meanwell.com/Upload/PDF/SD-350/SD-350-SPEC.PDF SD-350C] || DC-DC Converter || 36V || 72V || 5W? || 350W || 1x 4.5~5.5V/60A, 11~16V/27.5A, 23~30V/14.6A or 43~53V/7.3A output || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Meanwell || [https://www.meanwell.com/Upload/PDF/LDD-H/LDD-H-SPEC.PDF LDD-H series] || DC-DC LED Driver || 9V || 56V || 2W || 56W || Models with 300~1000mA CC, Vout: 2V~(Vin-3V). PWM (open collector/5V) in: 0.1~1KHz ||&lt;br /&gt;
|-&lt;br /&gt;
| Example || Example || Example || Example || Example || Example || Example || Example&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=270</id>
		<title>Wide Range Voltage Equipment</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=270"/>
		<updated>2020-08-20T21:31:58Z</updated>

		<summary type="html">&lt;p&gt;Teun: Edited in power columns (+details)&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;This is the start of a list for potential equipment that can handle a wide range of voltages.&lt;br /&gt;
I suggest that equipment is selected to have a wide voltage range so that power surges or brownouts don't cause equipment failure.&lt;br /&gt;
&lt;br /&gt;
Please add to the list, mentioning whether you have actually used the equipment, and whether it was any good.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Make !! Model !! Type !! Min. Voltage !! Max. Voltage !! Min. Power !! Max. Power !! Comments !! Actually used by&lt;br /&gt;
|-&lt;br /&gt;
| StarTech || [https://www.startech.com/uk/Cards-Adapters/USB-3.0/Hubs/~ST7300USBME ST7300USBME] || USB Hub / Charger || 7V || 48V || ? || 350W ? || Worked nicely at CCCamp 2019|| [[User:Chewie]]&lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://images-na.ssl-images-amazon.com/images/I/A1cHD8nc9FL.pdf TI-G102 (v1.0R)] || Gigabit Switch || 12V || 56V || 5.76W || 5.76W || 10x 1GB, 2 x SFP, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://www.trendnet.com/products/industrial-fiber-switches/TI-PG62B TI-PG62B] || Gigabit Switch || 12V || 56V || 5.76W || 120W || 4x 1GB PoE+, 2 x SPF, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| SystemBase || [https://www.sysbas.com/en/portfolio-item/sg-2021dilall/ SG-2021DIL] || Serial-&amp;gt;LAN Converter || 12V || 48V || 2W || 2W || Other Models are available with more or fewer ports|| &lt;br /&gt;
|-&lt;br /&gt;
| Meanwell || [https://www.meanwell.com/Upload/PDF/SD-350/SD-350-SPEC.PDF SD-350C] || DC-DC Converter || 36V || 72V || 5W? || 350W || 1x 4.5~5.5V/60A, 11~16V/27.5A, 23~30V/14.6A or 43~53V/7.3A output || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Mikrotik || [https://mikrotik.com/product/rb450gx4 RB-450Gx4] || PoE Gigabit Router || 10V || 57V || 4W || 16W || 5x 1Gb (1x 802.3at in, 1x PoE passthrough), 1x RS232, 2x DC input. 4x716MHz, 1G RAM, 512M Flash || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Example || Example || Example || Example || Example || Example || Example&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=269</id>
		<title>Wide Range Voltage Equipment</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=Wide_Range_Voltage_Equipment&amp;diff=269"/>
		<updated>2020-08-20T21:02:15Z</updated>

		<summary type="html">&lt;p&gt;Teun: Added devices&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;This is the start of a list for potential equipment that can handle a wide range of voltages.&lt;br /&gt;
I suggest that equipment is selected to have a wide voltage range so that power surges or brownouts don't cause equipment failure.&lt;br /&gt;
&lt;br /&gt;
Please add to the list, mentioning whether you have actually used the equipment, and whether it was any good.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Make !! Model !! Type !! Minimum Voltage !! Maximum Voltage !! Comments !! Actually used by&lt;br /&gt;
|-&lt;br /&gt;
| StarTech || [https://www.startech.com/uk/Cards-Adapters/USB-3.0/Hubs/~ST7300USBME ST7300USBME] || USB Hub / Charger || 7V || 48V || Worked nicely at CCCamp 2019|| [[User:Chewie]]&lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://images-na.ssl-images-amazon.com/images/I/A1cHD8nc9FL.pdf TI-G102 (v1.0R)] || Gigabit Switch || 12V || 56V || 10x 1GB, 2 x SFP, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| TRENDnet || [https://www.trendnet.com/products/industrial-fiber-switches/TI-PG62B TI-PG62B] || Gigabit Switch || 12V || 56V || 4x 1GB PoE+, 2 x SPF, dual power input + alarm || &lt;br /&gt;
|-&lt;br /&gt;
| SystemBase || [https://www.sysbas.com/en/portfolio-item/sg-2021dilall/ SG-2021DIL] || Serial-&amp;gt;LAN Converter || 12V || 48V || Other Models are available with more or fewer ports|| &lt;br /&gt;
|-&lt;br /&gt;
| Meanwell || [https://www.meanwell.com/Upload/PDF/SD-350/SD-350-SPEC.PDF SD-350] || DC-DC Converter || 36 || 72 || 350W 5/12/24/48V output || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Mikrotik || [https://mikrotik.com/product/rb450gx4 RB-450Gx4] || PoE Gigabit Router || 10 || 57 || 5x 1Gb (1x 802.3at in, 1x PoE passthrough), 1x RS232, 2x DC input. 4x716MHz, 1G RAM, 512M Flash || [[User:Teun]]&lt;br /&gt;
|-&lt;br /&gt;
| Example || Example || Example || Example || Example || Example || Example&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=Connectors&amp;diff=261</id>
		<title>Connectors</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=Connectors&amp;diff=261"/>
		<updated>2019-09-22T04:06:07Z</updated>

		<summary type="html">&lt;p&gt;Teun: /* Suggested Connectors */ Availability&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;One current problem we need to address is to choose a capable standard connector so that everyone can participate and prepare equipment before the next camp so that time is not wasted trying to connect everything together.&lt;br /&gt;
&lt;br /&gt;
The discussion tab can be used to debate the various types of connectors.&lt;br /&gt;
&lt;br /&gt;
It would be worth listing the connectors that have been tried but are not suitable with reasons too, for example, car cigarette connectors. Although rated for 10A, [https://altpwr.net/index.php?title=File:20190822_174525.jpg this] happened at 30V@5A.&lt;br /&gt;
&lt;br /&gt;
== Connector requirements ==&lt;br /&gt;
We have some requirements on our connectors which need to be met with varying importance. Key Words according to rfc2119. Please expand this list. :&lt;br /&gt;
&lt;br /&gt;
=== High Voltage Connectors ===&lt;br /&gt;
* Must have at least 3 Pins (PE, GND, V+)&lt;br /&gt;
* Must be lockable to prevent unplugging when loaded or alternatively this must be prevented by a different measure.&lt;br /&gt;
* Must be able to handle the load and voltages&lt;br /&gt;
* Should not be commonly used for different applications in a Camp context. If this cant be prevented damage to the different application and ours must not occur when connected with each other.&lt;br /&gt;
* Should be Waterproof&lt;br /&gt;
* May have added pins for communication. &amp;lt;- This may change to a &amp;quot;must have&amp;quot; depending on our implementation of load sharing.&lt;br /&gt;
* Must prevent touchable live connections. This may be implemented by a different measures.&lt;br /&gt;
 &lt;br /&gt;
=== Low Voltage (&amp;lt; 50VDC) Connectors  ===&lt;br /&gt;
* Should have at least 3 Pins (PE, GND, V+)&lt;br /&gt;
* Must be lockable to prevent unplugging when loaded or alternatively this must be prevented by a different measure.&lt;br /&gt;
* Must be able to handle the load and voltages&lt;br /&gt;
* Should not be commonly used for different applications in a Camp context. If this cant be prevented damage to the different application and ours must not occur when connected with each other.&lt;br /&gt;
* May have added pins for communication. &amp;lt;- This may change to a &amp;quot;must have&amp;quot; depending on our implementation of load sharing.&lt;br /&gt;
* Should prevent touchable live connections. This may be implemented by different measures&lt;br /&gt;
&lt;br /&gt;
== Suggested Connectors ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; style=&amp;quot;text-align: center; font-size: 85%; width: auto; table-layout: fixed;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Name !! Amps !! Volts !! Mating !! Contacts !! Lockable !! Water proof !! Finger safe !! 3 Pin !! Data !! Not Confusing !! Extendable !! Available&lt;br /&gt;
|-&lt;br /&gt;
| MC4 || 104 || 1500 || 100 || 1 || + || ++ || ++ || O || - || + || + || ++&lt;br /&gt;
|-&lt;br /&gt;
| XT60 || 30 || 500 || 1000 || 2 || O || -- || -- || - || - || O || + || +&lt;br /&gt;
|-&lt;br /&gt;
| Speakon || 20 || 250 || 5000 || 8 || ++ || + || ++ || + || + || -- || O || ++&lt;br /&gt;
|-&lt;br /&gt;
| XLR || 10 || 50 || 1000 || 7 || ++ || O || + || + || + || -- || + || ++&lt;br /&gt;
|-&lt;br /&gt;
| Wieland RST || 50 || 250 || 100 || 5 || ++ || ++ || ++ || ++ || + || + || + || -&lt;br /&gt;
|-&lt;br /&gt;
| Hirschmann CA || 10 || 230 || 500 || 6 || + || ++ || + || + || + || + || O || O&lt;br /&gt;
|-&lt;br /&gt;
| SELV || 16 || 50 || 250 || 2 || O || - || + || - || - || ++ || - || --&lt;br /&gt;
|-&lt;br /&gt;
| Anderson PP || 180 || 600 || 5000 || 10 || + || - || + || + || + || ++ || ++ || +&lt;br /&gt;
|-&lt;br /&gt;
| Anderson MP || 350 || 600 || 5000 || 2 || + || - || + || O || ++ || ++ || ++ || -&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/MC4_connector Multi-Contact 4] ===&lt;br /&gt;
[https://ec.staubli.com/AcroFiles/Technical%20Info/PV_SOL-LVDC_(en).pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 39~104A (depends on cable)&lt;br /&gt;
* Max Volts: 600~1500V (12kV surge)&lt;br /&gt;
* Mating cycles: 100x&lt;br /&gt;
* Number contacts: 1&lt;br /&gt;
* Ingress: IP65&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Approved for high voltage DC applications (IEC, TUV, UL)&lt;br /&gt;
* Waterproof IP65&lt;br /&gt;
* Availability / Fairly cheap&lt;br /&gt;
* Difficult to disconnect by accident&lt;br /&gt;
* While not recommended, designed to stop potential arcing on disconnect (an advantage over the [https://en.wikipedia.org/wiki/MC3_connector MC3 connectors])&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* PE, + and - connectors are separate cables.&lt;br /&gt;
* Should not be disconnected under load&lt;br /&gt;
* Difficult to disconnect without tools (can break)&lt;br /&gt;
* Low mating cycle count&lt;br /&gt;
&lt;br /&gt;
=== [https://m.youtube.com/watch?v=qEdysiZAYZ4 XT60] ===&lt;br /&gt;
[https://media.digikey.com/pdf/Data%20Sheets/DFRobot%20PDFs/FIT0587_Web.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 30A (60A peak)&lt;br /&gt;
* Max Volts: 500VDC&lt;br /&gt;
* Mating cycles: 1000x&lt;br /&gt;
* Number contacts: 2&lt;br /&gt;
* Ingress: IP00&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability / Cheap&lt;br /&gt;
* Small size&lt;br /&gt;
* 2 pole, one connector does both + and - wires&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Unsafe, contacts open when disconnected and possibly when connected&lt;br /&gt;
* Should not be disconnected under load&lt;br /&gt;
* Not waterproof / outdoor&lt;br /&gt;
* No 3 pin version with PE&lt;br /&gt;
&lt;br /&gt;
Suggested by [https://wiki.munichmakerlab.de/wiki/DC_Microgrid Munich Maker Lab] during camp&lt;br /&gt;
Page creator has no experience with this type of connector.&lt;br /&gt;
&lt;br /&gt;
=== [https://en.m.wikipedia.org/wiki/Speakon_connector Speakon] / [https://en.m.wikipedia.org/wiki/PowerCon PowerCon] ===&lt;br /&gt;
[https://www.neutrik.com/media/10094/download/product-guide---section-loundspeaker-connectors.pdf?v=1 datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 20A (40A AC continuous)&lt;br /&gt;
* Max Volts: 250V (4kV surge)&lt;br /&gt;
* Mating cycles: &amp;gt;5000x&lt;br /&gt;
* Number contacts: 4 or 8&lt;br /&gt;
* Ingress: IP54 (IP20 disconnected)&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability / Reasonable price&lt;br /&gt;
* Outdoor design UL/CSA approved (IP54 when connected)&lt;br /&gt;
* 4 or 8 pin versions&lt;br /&gt;
* Disconnect under load&lt;br /&gt;
* Locking&lt;br /&gt;
* High mating cycle count&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Designed/approved for AC&lt;br /&gt;
* No female plug (chassis/coupler only)&lt;br /&gt;
* Used for all sorts of stuff. Mistakes are more likely.&lt;br /&gt;
* Most cables only have 2 wires&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/XLR_connector XLR] ===&lt;br /&gt;
[https://www.neutrik.com/media/10098/download/product-guide---section-xlr.pdf?v=1 datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 16A 3p / 10A 4p / 7,5A 5~6p / 5A 7p&lt;br /&gt;
* Max Volts: 50V (1,5 kV surge)&lt;br /&gt;
* Mating cycles: &amp;gt;1000x&lt;br /&gt;
* Number contacts: 3~7 or 8+2 (Ethernet+power)&lt;br /&gt;
* Ingress: IP20 Female&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability&lt;br /&gt;
* Number of contacts (PE, data)&lt;br /&gt;
* Outdoor (IP40 or IP65)&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Low voltage / metal case&lt;br /&gt;
* Varying quality (fakes)&lt;br /&gt;
* Often used for small signals and stage equipment (audio / dmx etc.)&lt;br /&gt;
&lt;br /&gt;
=== [https://www.wieland-electric.com/en-gb/products/circular-connector-system-industry Wieland Gesis RST series] ===&lt;br /&gt;
[https://eshop.wieland-electric.com/categorie/en/circular-connector-system-in-raised-degree-of-protection-ip6x-gesis-rst/1000008683 specifications]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 16A (20A and 50A versions available)&lt;br /&gt;
* Max Volts: 250V (4kV surge)&lt;br /&gt;
* Mating cycles: 50~100x&lt;br /&gt;
* Number contacts: 3~5&lt;br /&gt;
* Ingress: IP68 (IP20 disconnected)&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Waterproof (IP66/68)&lt;br /&gt;
* Multiple contacts available (PE, data)&lt;br /&gt;
* Not commonly used (only 3p is sometimes used for 230VAC)&lt;br /&gt;
* Lots of accessories available (male / female / chassis / splitters etc.)&lt;br /&gt;
* Locking&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Availability, proprietary in Germany&lt;br /&gt;
* Not cheap&lt;br /&gt;
* Low mating cycle count&lt;br /&gt;
* No disconnect under load&lt;br /&gt;
&lt;br /&gt;
=== [http://www.hirschmann.de/en/Hirschmann_Produkte/Industrial_Connectors/Power_Connectors/CA_Series/index.phtml Hirschmann CA Series] ===&lt;br /&gt;
[https://catalog.belden.com//prodimgs/AllAssets-approved/EN/39/86/PDF_183986.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
[[File:Hirschmann CA-Series.png|thumb]]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 10A&lt;br /&gt;
* Max Volts: 230V (6kV surge)&lt;br /&gt;
* Mating cycles: 100~500x&lt;br /&gt;
* Number contacts: 3 or 6&lt;br /&gt;
* Ingress: IP67 (IP20 Disconnected Female)&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Waterproof (IP65, IP67)&lt;br /&gt;
* Multiple connectors&lt;br /&gt;
* Not commonly used&lt;br /&gt;
* Locking&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Availability, proprietary in Germany&lt;br /&gt;
* Not cheap (7€ plug, 3€ socket for 4 pole, 10€ plug, 7€ socket)&lt;br /&gt;
* No disconnect under load&lt;br /&gt;
* Extension and connection cords are different&lt;br /&gt;
&lt;br /&gt;
=== [https://www.breve.pl/pliki/2016/01/SELV-EN.pdf SELV Connectors] ===&lt;br /&gt;
[https://en.wikipedia.org/wiki/DC_connector#IEC_60906-3:1994 Details on the specs]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 16A&lt;br /&gt;
* Max Volts: 50V&lt;br /&gt;
* Mating cycles: Unknown&lt;br /&gt;
* Number contacts: 2&lt;br /&gt;
* Ingress: IP20 Female&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* 48V version specific for this purpose&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Only 2 pins&lt;br /&gt;
* Extremely rare&lt;br /&gt;
* Not water proof&lt;br /&gt;
* No female plug&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/Anderson_Powerpole Anderson Powerpole] ===&lt;br /&gt;
[http://www.farnell.com/datasheets/1922225.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 45A(55A) / 75A(120A) / 120A(240A) / 180A(350A)&lt;br /&gt;
* Max Volts: 600V (2200V dielectric)&lt;br /&gt;
* Mating cycles: &amp;gt;250x under load (&amp;gt;5000x probably)&lt;br /&gt;
* Number contacts: stackable in 2 dimensions&lt;br /&gt;
* Ingress: IP20 up to 45A version&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability (Ubiquitous worldwide, lot's of clones)&lt;br /&gt;
* Low price&lt;br /&gt;
* Disconnect under load&lt;br /&gt;
* Number of contacts, virtually unlimited&lt;br /&gt;
* Genderless, no male/female or direction exist&lt;br /&gt;
* Lots of versions (cable, chassis, pcb, rubber shroud, T-splitter)&lt;br /&gt;
* Colors available&lt;br /&gt;
* Pretty much touch-proof on both sides (rated IP20 up to 45A version)&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Not waterproof (except the shrouded premade connectors)&lt;br /&gt;
* Not touch-safe bigger versions&lt;br /&gt;
* Often used for 12 Volt DC (Amateur radio)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/Anderson_Powerpole Anderson Multipole SBE] ===&lt;br /&gt;
[http://www.farnell.com/datasheets/1922225.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 70A+20A / 175A+20A / 350A+20A&lt;br /&gt;
* Max Volts: 600V+200V (2200V dielectric)&lt;br /&gt;
* Mating cycles: &amp;gt;250x under load (&amp;gt;5000x probably)&lt;br /&gt;
* Number contacts: 2x Power and 2x PowerPole 20A or 2x PPMX (4x 5A pins)&lt;br /&gt;
* Ingress: IP20&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Often used in electric vehicles (durable)&lt;br /&gt;
* Disconnect under load&lt;br /&gt;
* High power&lt;br /&gt;
* Number of contacts, 8 data pins possible&lt;br /&gt;
* Genderless, no male/female or direction exist&lt;br /&gt;
* Lots of versions (cable, chassis, pcb, rubber shroud, T-splitter)&lt;br /&gt;
* Colors available&lt;br /&gt;
* Touch-proof on both sides (rated IP20)&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Not waterproof&lt;br /&gt;
* Not cheap&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=Connectors&amp;diff=260</id>
		<title>Connectors</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=Connectors&amp;diff=260"/>
		<updated>2019-09-22T03:55:31Z</updated>

		<summary type="html">&lt;p&gt;Teun: Nice little table&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;One current problem we need to address is to choose a capable standard connector so that everyone can participate and prepare equipment before the next camp so that time is not wasted trying to connect everything together.&lt;br /&gt;
&lt;br /&gt;
The discussion tab can be used to debate the various types of connectors.&lt;br /&gt;
&lt;br /&gt;
It would be worth listing the connectors that have been tried but are not suitable with reasons too, for example, car cigarette connectors. Although rated for 10A, [https://altpwr.net/index.php?title=File:20190822_174525.jpg this] happened at 30V@5A.&lt;br /&gt;
&lt;br /&gt;
== Connector requirements ==&lt;br /&gt;
We have some requirements on our connectors which need to be met with varying importance. Key Words according to rfc2119. Please expand this list. :&lt;br /&gt;
&lt;br /&gt;
=== High Voltage Connectors ===&lt;br /&gt;
* Must have at least 3 Pins (PE, GND, V+)&lt;br /&gt;
* Must be lockable to prevent unplugging when loaded or alternatively this must be prevented by a different measure.&lt;br /&gt;
* Must be able to handle the load and voltages&lt;br /&gt;
* Should not be commonly used for different applications in a Camp context. If this cant be prevented damage to the different application and ours must not occur when connected with each other.&lt;br /&gt;
* Should be Waterproof&lt;br /&gt;
* May have added pins for communication. &amp;lt;- This may change to a &amp;quot;must have&amp;quot; depending on our implementation of load sharing.&lt;br /&gt;
* Must prevent touchable live connections. This may be implemented by a different measures.&lt;br /&gt;
 &lt;br /&gt;
=== Low Voltage (&amp;lt; 50VDC) Connectors  ===&lt;br /&gt;
* Should have at least 3 Pins (PE, GND, V+)&lt;br /&gt;
* Must be lockable to prevent unplugging when loaded or alternatively this must be prevented by a different measure.&lt;br /&gt;
* Must be able to handle the load and voltages&lt;br /&gt;
* Should not be commonly used for different applications in a Camp context. If this cant be prevented damage to the different application and ours must not occur when connected with each other.&lt;br /&gt;
* May have added pins for communication. &amp;lt;- This may change to a &amp;quot;must have&amp;quot; depending on our implementation of load sharing.&lt;br /&gt;
* Should prevent touchable live connections. This may be implemented by different measures&lt;br /&gt;
&lt;br /&gt;
== Suggested Connectors ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; style=&amp;quot;text-align: center; font-size: 85%; width: auto; table-layout: fixed;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Name !! Amps !! Volts !! Mating !! Contacts !! Lockable !! Water proof !! Finger safe !! 3 Pin !! Data !! Not Confusing !! Extendable&lt;br /&gt;
|-&lt;br /&gt;
| MC4 || 104 || 1500 || 100 || 1 || + || ++ || ++ || O || - || + || +&lt;br /&gt;
|-&lt;br /&gt;
| XT60 || 30 || 500 || 1000 || 2 || O || -- || -- || - || - || O || +&lt;br /&gt;
|-&lt;br /&gt;
| Speakon || 20 || 250 || 5000 || 8 || ++ || + || ++ || + || + || -- || O&lt;br /&gt;
|-&lt;br /&gt;
| XLR || 10 || 50 || 1000 || 7 || ++ || O || + || + || + || -- || +&lt;br /&gt;
|-&lt;br /&gt;
| Wieland RST || 50 || 250 || 100 || 5 || ++ || ++ || ++ || ++ || + || + || +&lt;br /&gt;
|-&lt;br /&gt;
| Hirschmann CA || 10 || 230 || 500 || 6 || + || ++ || + || + || + || + || O&lt;br /&gt;
|-&lt;br /&gt;
| SELV || 16 || 50 || 250 || 2 || O || - || + || - || - || ++ || -&lt;br /&gt;
|-&lt;br /&gt;
| Anderson PP || 180 || 600 || 5000 || 10 || + || - || + || + || + || ++ || ++&lt;br /&gt;
|-&lt;br /&gt;
| Anderson MP || 350 || 600 || 5000 || 2 || + || - || + || O || ++ || ++ || ++&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/MC4_connector Multi-Contact 4] ===&lt;br /&gt;
[https://ec.staubli.com/AcroFiles/Technical%20Info/PV_SOL-LVDC_(en).pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 39~104A (depends on cable)&lt;br /&gt;
* Max Volts: 600~1500V (12kV surge)&lt;br /&gt;
* Mating cycles: 100x&lt;br /&gt;
* Number contacts: 1&lt;br /&gt;
* Ingress: IP65&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Approved for high voltage DC applications (IEC, TUV, UL)&lt;br /&gt;
* Waterproof IP65&lt;br /&gt;
* Availability / Fairly cheap&lt;br /&gt;
* Difficult to disconnect by accident&lt;br /&gt;
* While not recommended, designed to stop potential arcing on disconnect (an advantage over the [https://en.wikipedia.org/wiki/MC3_connector MC3 connectors])&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* PE, + and - connectors are separate cables.&lt;br /&gt;
* Should not be disconnected under load&lt;br /&gt;
* Difficult to disconnect without tools (can break)&lt;br /&gt;
* Low mating cycle count&lt;br /&gt;
&lt;br /&gt;
=== [https://m.youtube.com/watch?v=qEdysiZAYZ4 XT60] ===&lt;br /&gt;
[https://media.digikey.com/pdf/Data%20Sheets/DFRobot%20PDFs/FIT0587_Web.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 30A (60A peak)&lt;br /&gt;
* Max Volts: 500VDC&lt;br /&gt;
* Mating cycles: 1000x&lt;br /&gt;
* Number contacts: 2&lt;br /&gt;
* Ingress: IP00&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability / Cheap&lt;br /&gt;
* Small size&lt;br /&gt;
* 2 pole, one connector does both + and - wires&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Unsafe, contacts open when disconnected and possibly when connected&lt;br /&gt;
* Should not be disconnected under load&lt;br /&gt;
* Not waterproof / outdoor&lt;br /&gt;
* No 3 pin version with PE&lt;br /&gt;
&lt;br /&gt;
Suggested by [https://wiki.munichmakerlab.de/wiki/DC_Microgrid Munich Maker Lab] during camp&lt;br /&gt;
Page creator has no experience with this type of connector.&lt;br /&gt;
&lt;br /&gt;
=== [https://en.m.wikipedia.org/wiki/Speakon_connector Speakon] / [https://en.m.wikipedia.org/wiki/PowerCon PowerCon] ===&lt;br /&gt;
[https://www.neutrik.com/media/10094/download/product-guide---section-loundspeaker-connectors.pdf?v=1 datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 20A (40A AC continuous)&lt;br /&gt;
* Max Volts: 250V (4kV surge)&lt;br /&gt;
* Mating cycles: &amp;gt;5000x&lt;br /&gt;
* Number contacts: 4 or 8&lt;br /&gt;
* Ingress: IP54 (IP20 disconnected)&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability / Reasonable price&lt;br /&gt;
* Outdoor design UL/CSA approved (IP54 when connected)&lt;br /&gt;
* 4 or 8 pin versions&lt;br /&gt;
* Disconnect under load&lt;br /&gt;
* Locking&lt;br /&gt;
* High mating cycle count&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Designed/approved for AC&lt;br /&gt;
* No female plug (chassis/coupler only)&lt;br /&gt;
* Used for all sorts of stuff. Mistakes are more likely.&lt;br /&gt;
* Most cables only have 2 wires&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/XLR_connector XLR] ===&lt;br /&gt;
[https://www.neutrik.com/media/10098/download/product-guide---section-xlr.pdf?v=1 datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 16A 3p / 10A 4p / 7,5A 5~6p / 5A 7p&lt;br /&gt;
* Max Volts: 50V (1,5 kV surge)&lt;br /&gt;
* Mating cycles: &amp;gt;1000x&lt;br /&gt;
* Number contacts: 3~7 or 8+2 (Ethernet+power)&lt;br /&gt;
* Ingress: IP20 Female&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability&lt;br /&gt;
* Number of contacts (PE, data)&lt;br /&gt;
* Outdoor (IP40 or IP65)&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Low voltage / metal case&lt;br /&gt;
* Varying quality (fakes)&lt;br /&gt;
* Often used for small signals and stage equipment (audio / dmx etc.)&lt;br /&gt;
&lt;br /&gt;
=== [https://www.wieland-electric.com/en-gb/products/circular-connector-system-industry Wieland Gesis RST series] ===&lt;br /&gt;
[https://eshop.wieland-electric.com/categorie/en/circular-connector-system-in-raised-degree-of-protection-ip6x-gesis-rst/1000008683 specifications]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 16A (20A and 50A versions available)&lt;br /&gt;
* Max Volts: 250V (4kV surge)&lt;br /&gt;
* Mating cycles: 50~100x&lt;br /&gt;
* Number contacts: 3~5&lt;br /&gt;
* Ingress: IP68 (IP20 disconnected)&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Waterproof (IP66/68)&lt;br /&gt;
* Multiple contacts available (PE, data)&lt;br /&gt;
* Not commonly used (only 3p is sometimes used for 230VAC)&lt;br /&gt;
* Lots of accessories available (male / female / chassis / splitters etc.)&lt;br /&gt;
* Locking&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Availability, proprietary in Germany&lt;br /&gt;
* Not cheap&lt;br /&gt;
* Low mating cycle count&lt;br /&gt;
* No disconnect under load&lt;br /&gt;
&lt;br /&gt;
=== [http://www.hirschmann.de/en/Hirschmann_Produkte/Industrial_Connectors/Power_Connectors/CA_Series/index.phtml Hirschmann CA Series] ===&lt;br /&gt;
[https://catalog.belden.com//prodimgs/AllAssets-approved/EN/39/86/PDF_183986.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
[[File:Hirschmann CA-Series.png|thumb]]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 10A&lt;br /&gt;
* Max Volts: 230V (6kV surge)&lt;br /&gt;
* Mating cycles: 100~500x&lt;br /&gt;
* Number contacts: 3 or 6&lt;br /&gt;
* Ingress: IP67 (IP20 Disconnected Female)&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Waterproof (IP65, IP67)&lt;br /&gt;
* Multiple connectors&lt;br /&gt;
* Not commonly used&lt;br /&gt;
* Locking&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Availability, proprietary in Germany&lt;br /&gt;
* Not cheap (7€ plug, 3€ socket for 4 pole, 10€ plug, 7€ socket)&lt;br /&gt;
* No disconnect under load&lt;br /&gt;
* Extension and connection cords are different&lt;br /&gt;
&lt;br /&gt;
=== [https://www.breve.pl/pliki/2016/01/SELV-EN.pdf SELV Connectors] ===&lt;br /&gt;
[https://en.wikipedia.org/wiki/DC_connector#IEC_60906-3:1994 Details on the specs]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 16A&lt;br /&gt;
* Max Volts: 50V&lt;br /&gt;
* Mating cycles: Unknown&lt;br /&gt;
* Number contacts: 2&lt;br /&gt;
* Ingress: IP20 Female&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* 48V version specific for this purpose&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Only 2 pins&lt;br /&gt;
* Extremely rare&lt;br /&gt;
* Not water proof&lt;br /&gt;
* No female plug&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/Anderson_Powerpole Anderson Powerpole] ===&lt;br /&gt;
[http://www.farnell.com/datasheets/1922225.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 45A(55A) / 75A(120A) / 120A(240A) / 180A(350A)&lt;br /&gt;
* Max Volts: 600V (2200V dielectric)&lt;br /&gt;
* Mating cycles: &amp;gt;250x under load (&amp;gt;5000x probably)&lt;br /&gt;
* Number contacts: stackable in 2 dimensions&lt;br /&gt;
* Ingress: IP20 up to 45A version&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability (Ubiquitous worldwide, lot's of clones)&lt;br /&gt;
* Low price&lt;br /&gt;
* Disconnect under load&lt;br /&gt;
* Number of contacts, virtually unlimited&lt;br /&gt;
* Genderless, no male/female or direction exist&lt;br /&gt;
* Lots of versions (cable, chassis, pcb, rubber shroud, T-splitter)&lt;br /&gt;
* Colors available&lt;br /&gt;
* Pretty much touch-proof on both sides (rated IP20 up to 45A version)&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Not waterproof (except the shrouded premade connectors)&lt;br /&gt;
* Not touch-safe bigger versions&lt;br /&gt;
* Often used for 12 Volt DC (Amateur radio)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/Anderson_Powerpole Anderson Multipole SBE] ===&lt;br /&gt;
[http://www.farnell.com/datasheets/1922225.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 70A+20A / 175A+20A / 350A+20A&lt;br /&gt;
* Max Volts: 600V+200V (2200V dielectric)&lt;br /&gt;
* Mating cycles: &amp;gt;250x under load (&amp;gt;5000x probably)&lt;br /&gt;
* Number contacts: 2x Power and 2x PowerPole 20A or 2x PPMX (4x 5A pins)&lt;br /&gt;
* Ingress: IP20&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Often used in electric vehicles (durable)&lt;br /&gt;
* Disconnect under load&lt;br /&gt;
* High power&lt;br /&gt;
* Number of contacts, 8 data pins possible&lt;br /&gt;
* Genderless, no male/female or direction exist&lt;br /&gt;
* Lots of versions (cable, chassis, pcb, rubber shroud, T-splitter)&lt;br /&gt;
* Colors available&lt;br /&gt;
* Touch-proof on both sides (rated IP20)&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Not waterproof&lt;br /&gt;
* Not cheap&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=Connectors&amp;diff=259</id>
		<title>Connectors</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=Connectors&amp;diff=259"/>
		<updated>2019-09-22T03:02:04Z</updated>

		<summary type="html">&lt;p&gt;Teun: /* Suggested Connectors */ Cleanup ;)&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;One current problem we need to address is to choose a capable standard connector so that everyone can participate and prepare equipment before the next camp so that time is not wasted trying to connect everything together.&lt;br /&gt;
&lt;br /&gt;
The discussion tab can be used to debate the various types of connectors.&lt;br /&gt;
&lt;br /&gt;
It would be worth listing the connectors that have been tried but are not suitable with reasons too, for example, car cigarette connectors. Although rated for 10A, [https://altpwr.net/index.php?title=File:20190822_174525.jpg this] happened at 30V@5A.&lt;br /&gt;
&lt;br /&gt;
== Connector requirements ==&lt;br /&gt;
We have some requirements on our connectors which need to be met with varying importance. Key Words according to rfc2119. Please expand this list. :&lt;br /&gt;
&lt;br /&gt;
=== High Voltage Connectors ===&lt;br /&gt;
* Must have at least 3 Pins (PE, GND, V+)&lt;br /&gt;
* Must be lockable to prevent unplugging when loaded or alternatively this must be prevented by a different measure.&lt;br /&gt;
* Must be able to handle the load and voltages&lt;br /&gt;
* Should not be commonly used for different applications in a Camp context. If this cant be prevented damage to the different application and ours must not occur when connected with each other.&lt;br /&gt;
* Should be Waterproof&lt;br /&gt;
* May have added pins for communication. &amp;lt;- This may change to a &amp;quot;must have&amp;quot; depending on our implementation of load sharing.&lt;br /&gt;
* Must prevent touchable live connections. This may be implemented by a different measures.&lt;br /&gt;
 &lt;br /&gt;
=== Low Voltage (&amp;lt; 50VDC) Connectors  ===&lt;br /&gt;
* Should have at least 3 Pins (PE, GND, V+)&lt;br /&gt;
* Must be lockable to prevent unplugging when loaded or alternatively this must be prevented by a different measure.&lt;br /&gt;
* Must be able to handle the load and voltages&lt;br /&gt;
* Should not be commonly used for different applications in a Camp context. If this cant be prevented damage to the different application and ours must not occur when connected with each other.&lt;br /&gt;
* May have added pins for communication. &amp;lt;- This may change to a &amp;quot;must have&amp;quot; depending on our implementation of load sharing.&lt;br /&gt;
* Should prevent touchable live connections. This may be implemented by different measures&lt;br /&gt;
&lt;br /&gt;
== Suggested Connectors ==&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/MC4_connector Multi-Contact 4] ===&lt;br /&gt;
[https://ec.staubli.com/AcroFiles/Technical%20Info/PV_SOL-LVDC_(en).pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 39~104A (depends on cable)&lt;br /&gt;
* Max Volts: 600~1500V (12kV surge)&lt;br /&gt;
* Mating cycles: 100x&lt;br /&gt;
* Number contacts: 1&lt;br /&gt;
* Ingress: IP65&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Approved for high voltage DC applications (IEC, TUV, UL)&lt;br /&gt;
* Waterproof IP65&lt;br /&gt;
* Availability / Fairly cheap&lt;br /&gt;
* Difficult to disconnect by accident&lt;br /&gt;
* While not recommended, designed to stop potential arcing on disconnect (an advantage over the [https://en.wikipedia.org/wiki/MC3_connector MC3 connectors])&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* PE, + and - connectors are separate cables.&lt;br /&gt;
* Should not be disconnected under load&lt;br /&gt;
* Difficult to disconnect without tools (can break)&lt;br /&gt;
* Low mating cycle count&lt;br /&gt;
&lt;br /&gt;
=== [https://m.youtube.com/watch?v=qEdysiZAYZ4 XT60] ===&lt;br /&gt;
[https://media.digikey.com/pdf/Data%20Sheets/DFRobot%20PDFs/FIT0587_Web.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 30A (60A peak)&lt;br /&gt;
* Max Volts: 500VDC&lt;br /&gt;
* Mating cycles: 1000x&lt;br /&gt;
* Number contacts: 2&lt;br /&gt;
* Ingress: IP00&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability / Cheap&lt;br /&gt;
* Small size&lt;br /&gt;
* 2 pole, one connector does both + and - wires&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Unsafe, contacts open when disconnected and possibly when connected&lt;br /&gt;
* Should not be disconnected under load&lt;br /&gt;
* Not waterproof / outdoor&lt;br /&gt;
* No 3 pin version with PE&lt;br /&gt;
&lt;br /&gt;
Suggested by [https://wiki.munichmakerlab.de/wiki/DC_Microgrid Munich Maker Lab] during camp&lt;br /&gt;
Page creator has no experience with this type of connector.&lt;br /&gt;
&lt;br /&gt;
=== [https://en.m.wikipedia.org/wiki/Speakon_connector Speakon] / [https://en.m.wikipedia.org/wiki/PowerCon PowerCon] ===&lt;br /&gt;
[https://www.neutrik.com/media/10094/download/product-guide---section-loundspeaker-connectors.pdf?v=1 datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 20A (40A AC continuous)&lt;br /&gt;
* Max Volts: 250V (4kV surge)&lt;br /&gt;
* Mating cycles: &amp;gt;5000x&lt;br /&gt;
* Number contacts: 4 or 8&lt;br /&gt;
* Ingress: IP54 (IP20 disconnected)&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability / Reasonable price&lt;br /&gt;
* Outdoor design UL/CSA approved (IP54 when connected)&lt;br /&gt;
* 4 or 8 pin versions&lt;br /&gt;
* Disconnect under load&lt;br /&gt;
* Locking&lt;br /&gt;
* High mating cycle count&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Designed/approved for AC&lt;br /&gt;
* No female plug (chassis/coupler only)&lt;br /&gt;
* Used for all sorts of stuff. Mistakes are more likely.&lt;br /&gt;
* Most cables only have 2 wires&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/XLR_connector XLR] ===&lt;br /&gt;
[https://www.neutrik.com/media/10098/download/product-guide---section-xlr.pdf?v=1 datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 16A 3p / 10A 4p / 7,5A 5~6p / 5A 7p&lt;br /&gt;
* Max Volts: 50V (1,5 kV surge)&lt;br /&gt;
* Mating cycles: &amp;gt;1000x&lt;br /&gt;
* Number contacts: 3~7 or 8+2 (Ethernet+power)&lt;br /&gt;
* Ingress: IP20 Female&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability&lt;br /&gt;
* Number of contacts (PE, data)&lt;br /&gt;
* Outdoor (IP40 or IP65)&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Low voltage / metal case&lt;br /&gt;
* Varying quality (fakes)&lt;br /&gt;
* Often used for small signals and stage equipment (audio / dmx etc.)&lt;br /&gt;
&lt;br /&gt;
=== [https://www.wieland-electric.com/en-gb/products/circular-connector-system-industry Wieland Gesis RST series] ===&lt;br /&gt;
[https://eshop.wieland-electric.com/categorie/en/circular-connector-system-in-raised-degree-of-protection-ip6x-gesis-rst/1000008683 specifications]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 16A (20A and 50A versions available)&lt;br /&gt;
* Max Volts: 250V (4kV surge)&lt;br /&gt;
* Mating cycles: 50~100x&lt;br /&gt;
* Number contacts: 3~5&lt;br /&gt;
* Ingress: IP68 (IP20 disconnected)&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Waterproof (IP66/68)&lt;br /&gt;
* Multiple contacts available (PE, data)&lt;br /&gt;
* Not commonly used (only 3p is sometimes used for 230VAC)&lt;br /&gt;
* Lots of accessories available (male / female / chassis / splitters etc.)&lt;br /&gt;
* Locking&lt;br /&gt;
* Extension cords are possible&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Availability, proprietary in Germany&lt;br /&gt;
* Not cheap&lt;br /&gt;
* Low mating cycle count&lt;br /&gt;
* No disconnect under load&lt;br /&gt;
&lt;br /&gt;
=== [http://www.hirschmann.de/en/Hirschmann_Produkte/Industrial_Connectors/Power_Connectors/CA_Series/index.phtml Hirschmann CA Series] ===&lt;br /&gt;
[https://catalog.belden.com//prodimgs/AllAssets-approved/EN/39/86/PDF_183986.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
[[File:Hirschmann CA-Series.png|thumb]]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 10A&lt;br /&gt;
* Max Volts: 230V (6kV surge)&lt;br /&gt;
* Mating cycles: 100~500x&lt;br /&gt;
* Number contacts: 3 or 6&lt;br /&gt;
* Ingress: IP67 (IP20 Disconnected Female)&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Waterproof (IP65, IP67)&lt;br /&gt;
* Multiple connectors&lt;br /&gt;
* Not commonly used&lt;br /&gt;
* Locking&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Availability, proprietary in Germany&lt;br /&gt;
* Not cheap (7€ plug, 3€ socket for 4 pole, 10€ plug, 7€ socket)&lt;br /&gt;
* No disconnect under load&lt;br /&gt;
* Extension and connection cords are different&lt;br /&gt;
&lt;br /&gt;
=== [https://www.breve.pl/pliki/2016/01/SELV-EN.pdf SELV Connectors] ===&lt;br /&gt;
[https://en.wikipedia.org/wiki/DC_connector#IEC_60906-3:1994 Details on the specs]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 16A&lt;br /&gt;
* Max Volts: 50V&lt;br /&gt;
* Mating cycles: Unknown&lt;br /&gt;
* Number contacts: 2&lt;br /&gt;
* Ingress: IP20 Female&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* 48V version specific for this purpose&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Only 2 pins&lt;br /&gt;
* Extremely rare&lt;br /&gt;
* Not water proof&lt;br /&gt;
* No female plug&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/Anderson_Powerpole Anderson Powerpole] ===&lt;br /&gt;
[http://www.farnell.com/datasheets/1922225.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 45A(55A) / 75A(120A) / 120A(240A) / 180A(350A)&lt;br /&gt;
* Max Volts: 600V (2200V dielectric)&lt;br /&gt;
* Mating cycles: &amp;gt;250x under load (&amp;gt;5000x probably)&lt;br /&gt;
* Number contacts: stackable in 2 dimensions&lt;br /&gt;
* Ingress: IP20 up to 45A version&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Availability (Ubiquitous worldwide, lot's of clones)&lt;br /&gt;
* Low price&lt;br /&gt;
* Disconnect under load&lt;br /&gt;
* Number of contacts, virtually unlimited&lt;br /&gt;
* Genderless, no male/female or direction exist&lt;br /&gt;
* Lots of versions (cable, chassis, pcb, rubber shroud, T-splitter)&lt;br /&gt;
* Colors available&lt;br /&gt;
* Pretty much touch-proof on both sides (rated IP20 up to 45A version)&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Not waterproof (except the shrouded premade connectors)&lt;br /&gt;
* Not touch-safe bigger versions&lt;br /&gt;
* Often used for 12 Volt DC (Amateur radio)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== [https://en.wikipedia.org/wiki/Anderson_Powerpole Anderson Multipole SBE] ===&lt;br /&gt;
[http://www.farnell.com/datasheets/1922225.pdf datasheet]&lt;br /&gt;
&lt;br /&gt;
Technical Specifications:&lt;br /&gt;
* Max Amps: 70A+20A / 175A+20A / 350A+20A&lt;br /&gt;
* Max Volts: 600V+200V (2200V dielectric)&lt;br /&gt;
* Mating cycles: &amp;gt;250x under load (&amp;gt;5000x probably)&lt;br /&gt;
* Number contacts: 2x Power and 2x PowerPole 20A or 2x PPMX (4x 5A pins)&lt;br /&gt;
* Ingress: IP20&lt;br /&gt;
&lt;br /&gt;
Pros:&lt;br /&gt;
* Often used in electric vehicles (durable)&lt;br /&gt;
* Disconnect under load&lt;br /&gt;
* High power&lt;br /&gt;
* Number of contacts, 8 data pins possible&lt;br /&gt;
* Genderless, no male/female or direction exist&lt;br /&gt;
* Lots of versions (cable, chassis, pcb, rubber shroud, T-splitter)&lt;br /&gt;
* Colors available&lt;br /&gt;
* Touch-proof on both sides (rated IP20)&lt;br /&gt;
&lt;br /&gt;
Cons:&lt;br /&gt;
* Not waterproof&lt;br /&gt;
* Not cheap&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=User:Teun&amp;diff=258</id>
		<title>User:Teun</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=User:Teun&amp;diff=258"/>
		<updated>2019-09-21T23:54:01Z</updated>

		<summary type="html">&lt;p&gt;Teun: .&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* '''Name:''' Teun Kloosterman&lt;br /&gt;
* '''E-mail:''' teun@teun.cz&lt;br /&gt;
* '''IM:''' Riot: @tkteun:disroot.org Telegram: @tkteun&lt;br /&gt;
* '''Callsign:''' PA3TK&lt;br /&gt;
* '''Languages:''' Dutch/English&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Living off-grid with 11 people for the past 5 years.&lt;br /&gt;
&lt;br /&gt;
System setup consisting of:&lt;br /&gt;
- 16x Solar panels 270Wp&lt;br /&gt;
- 12x Hoppecke Trak Air Lead acid batteries (recycled, ex-lease)&lt;br /&gt;
- Victron Phoenix Multi 24V (2nd hand, ex yacht)&lt;br /&gt;
- Victron MPPTs&lt;br /&gt;
- Victron BMV&lt;br /&gt;
- Whisper Tech Whispergen - Sterling Generator (saved, ex yacht)&lt;br /&gt;
&lt;br /&gt;
We have about 50 Watt stand-by usage with internet etc., this is raised to about 600 Watt with LED lights, computers, phone charging and music. This works for about 9 months a year with at least 6 months without worries. For the remaining dark period, the Whispergen sterling motor supplies 600-1000 Watt and heats a 1000 ltr. storage tank with about 4 kW using about 0.5 ltr. Diesel per hour (&amp;gt;95% efficient). We use between 600 and 1200 ltr. of Diesel fuel per year depending on weather conditions and occupancy.&lt;br /&gt;
&lt;br /&gt;
https://altpwr.net/images/4/49/Jeltje_powerwall.jpg&lt;br /&gt;
https://altpwr.net/images/9/9e/Whispergen.jpg&lt;br /&gt;
&lt;br /&gt;
[[File:Jeltje powerwall.jpg]]&lt;br /&gt;
[[File:Whispergen.jpg]]&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=User:Teun&amp;diff=257</id>
		<title>User:Teun</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=User:Teun&amp;diff=257"/>
		<updated>2019-09-21T23:51:17Z</updated>

		<summary type="html">&lt;p&gt;Teun: Pictures seem broken&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* '''Name:''' Teun Kloosterman&lt;br /&gt;
* '''E-mail:''' teun@teun.cz&lt;br /&gt;
* '''IM:''' Riot: @tkteun:disroot.org Telegram: @tkteun&lt;br /&gt;
* '''Callsign:''' PA3TK&lt;br /&gt;
* '''Languages:''' Dutch/English&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Living off-grid with 11 people for the past 5 years.&lt;br /&gt;
&lt;br /&gt;
System setup consisting of:&lt;br /&gt;
- 16x Solar panels 270Wp&lt;br /&gt;
- 12x Hoppecke Trak Air Lead acid batteries (recycled, ex-lease)&lt;br /&gt;
- Victron Phoenix Multi 24V (2nd hand, ex yacht)&lt;br /&gt;
- Victron MPPTs&lt;br /&gt;
- Victron BMV&lt;br /&gt;
- Whisper Tech Whispergen - Sterling Generator (saved, ex yacht)&lt;br /&gt;
&lt;br /&gt;
We have about 50 Watt stand-by usage with internet etc., this is raised to about 600 Watt with LED lights, computers, phone charging and music. This works for about 9 months a year with at least 6 months without worries. For the remaining dark period, the Whispergen sterling motor supplies 600-1000 Watt and heats a 1000 ltr. storage tank with about 4 kW using about 0.5 ltr. Diesel per hour (&amp;gt;95% efficient). We use between 600 and 1200 ltr. of Diesel fuel per year depending on weather conditions and occupancy.&lt;br /&gt;
&lt;br /&gt;
[[File:Jeltje powerwall.jpg]]&lt;br /&gt;
&lt;br /&gt;
[[File:Whispergen.jpg]]&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=User:Teun&amp;diff=256</id>
		<title>User:Teun</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=User:Teun&amp;diff=256"/>
		<updated>2019-09-21T23:50:33Z</updated>

		<summary type="html">&lt;p&gt;Teun: Added power setup&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* '''Name:''' Teun Kloosterman&lt;br /&gt;
* '''E-mail:''' teun@teun.cz&lt;br /&gt;
* '''IM:''' Riot: @tkteun:disroot.org Telegram: @tkteun&lt;br /&gt;
* '''Callsign:''' PA3TK&lt;br /&gt;
* '''Languages:''' Dutch/English&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Living off-grid with 11 people for the past 5 years.&lt;br /&gt;
&lt;br /&gt;
System setup consisting of:&lt;br /&gt;
- 16x Solar panels 270Wp&lt;br /&gt;
- 12x Hoppecke Trak Air Lead acid batteries (recycled, ex-lease)&lt;br /&gt;
- Victron Phoenix Multi 24V (2nd hand, ex yacht)&lt;br /&gt;
- Victron MPPTs&lt;br /&gt;
- Victron BMV&lt;br /&gt;
- Whisper Tech Whispergen - Sterling Generator (saved, ex yacht)&lt;br /&gt;
&lt;br /&gt;
We have about 50 Watt stand-by usage with internet etc., this is raised to about 600 Watt with LED lights, computers, phone charging and music. This works for about 9 months a year with at least 6 months without worries. For the remaining dark period, the Whispergen sterling motor supplies 600-1000 Watt and heats a 1000 ltr. storage tank with about 4 kW using about 0.5 ltr. Diesel per hour (&amp;gt;95% efficient). We use between 600 and 1200 ltr. of Diesel fuel per year depending on weather conditions and occupancy.&lt;br /&gt;
&lt;br /&gt;
[[File:Jeltje powerwall.jpg|640px|frame|left]]&lt;br /&gt;
&lt;br /&gt;
[[File:Whispergen.jpg|640px|frame|left]]&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=File:Whispergen.jpg&amp;diff=255</id>
		<title>File:Whispergen.jpg</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=File:Whispergen.jpg&amp;diff=255"/>
		<updated>2019-09-21T23:33:53Z</updated>

		<summary type="html">&lt;p&gt;Teun: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;1KW Sterling Engine by Whisper Tech Ltd. Christchurch NZ&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=File:Jeltje_powerwall.jpg&amp;diff=254</id>
		<title>File:Jeltje powerwall.jpg</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=File:Jeltje_powerwall.jpg&amp;diff=254"/>
		<updated>2019-09-21T23:18:06Z</updated>

		<summary type="html">&lt;p&gt;Teun: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Off-grid setup for the past decade&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=User:Teun&amp;diff=114</id>
		<title>User:Teun</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=User:Teun&amp;diff=114"/>
		<updated>2019-08-27T11:03:31Z</updated>

		<summary type="html">&lt;p&gt;Teun: .&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* '''Name:''' Teun Kloosterman&lt;br /&gt;
* '''E-mail:''' teun@teun.cz&lt;br /&gt;
* '''IM:''' Riot: @tkteun:disroot.org Telegram: @tkteun&lt;br /&gt;
* '''Callsign:''' PA3TK&lt;br /&gt;
* '''Languages:''' Dutch/English&lt;br /&gt;
* '''Experience in electrical engineering:''' Studied for a while, hobby etc.&lt;br /&gt;
* '''Experience in PV-systems:''' Some installation experience&lt;/div&gt;</summary>
		<author><name>Teun</name></author>
		
	</entry>
	<entry>
		<id>http://altpwr.net/index.php?title=Political_ideas&amp;diff=113</id>
		<title>Political ideas</title>
		<link rel="alternate" type="text/html" href="http://altpwr.net/index.php?title=Political_ideas&amp;diff=113"/>
		<updated>2019-08-27T10:58:10Z</updated>

		<summary type="html">&lt;p&gt;Teun: Flexible work hours&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=== Important: Be positive, suggest general solutions, don't address parties or politicians. ===&lt;br /&gt;
&lt;br /&gt;
'''Things below are just brainfarts, add your own!'''&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''In the Netherlands, traffic is getting worse everyday. Air pollution is above the allowed maximum. How to solve this? (Might apply to other countries too.)'''&lt;br /&gt;
* Promote working nearby home. Governmental employers first to set the tone, accept new employees only if living nearby. Make job swapping easier. Don't let employers pay for fuel or lease out diesel or petrol fuel powered cars.&lt;br /&gt;
* Make petrol, gas and diesel much more expensive, make electric or H2 cars cheaper, improve public transport.&lt;br /&gt;
* Maximum speed for all traffic at 90kph. It sounds stupid, but this helps to get faster to work with less fuel consumption. Why?&lt;br /&gt;
** A lot less jams and ghost jams, trucks are not mobile roadblocks anymore as they travel at the same speed, safety is improved, car density can go up, less accidents.&lt;br /&gt;
** Maximum speed is lower, but average speed goes up and people get more relaxed and less agitated,  less health costs!&lt;br /&gt;
** Air pollution drops significantly as it is more efficient to drive slower and on a more even speed. As a result you'll have less health costs again!&lt;br /&gt;
** Many of the speed signs can disappear, this also saves a lot of money.&lt;br /&gt;
* Force employers to use flexible work hours / Change minimum office hours to 10:30~15:00. Also make Saturday an office day for flexibility. Will reduce traffic jams and allow for couples to have simpler solutions with kids. Can also stimulate public transport because of less congestion.&lt;br /&gt;
&lt;br /&gt;
'''Everybody has the right to get a kid(s), but this planet is getting too crowded.''' &lt;br /&gt;
This problem should be discussed more frequently and openly to the public. If a population decreases in a country it is not always a bad thing! It would be great if the planet population increase can be halted or even slightly reversed. &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''Economical growth should not be a goal ever, economical sustainability with the main goal to reduce pollution is a lot better.'''&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''Lithium battery regulations.'''&lt;br /&gt;
Lithium is not that abundant on our planet and batteries are hard (and expensive) to recycle. Most batteries embedded in devices such as mobile phones get charged to 100% each cycle. If this is limited to 80%, most batteries will last up to 5 times longer! There should be regulations in place to prevent this abuse! It is very easy to develop cheap electronic battery management systems that make batteries last longer, but they are hard to find on the market.&lt;/div&gt;</summary>